Product Details:
Model Name/Number | XA 900 |
Power Source | 3 x AA (R6) alkaline dry cells |
Operating Temperature Range | -10 to 40 Deg C |
Weight | 165 g |
We offer high quality toxic gas detector for detecting various types of gases, including hydrogen sulfide, carbon monoxide, combustible gases and more. Based on latest technology, toxic gas detectors are quality and sensitivity and their ability to perform comprehensive testing and detection. All the instruments in our range of toxic gas detector is specifically designed to deliver you with the utmost in precision and reliability. We provide various kinds of toxic gas detector and gas detecting system like toxic gas detector, toxic gas detection system, hydrogen sulfide detectors, hydrogen sulfide gas detectors, multi gas detector, multi gas leak detector and toxic gas monitor.
XA 900 Multi gas Detector XA 900 is a multi gas detector that can be used for the detection of oxygen, combustible gases, hydrogen sulfide and carbon monoxide. The instruments in this series works on different principles, including – catalytic combustion, galvanic cell and electrochemical cell. Available at industry leading prices, the device offers reliable performance and accuracy.
Features:- A range of gas variations are possible by combining detected gases. Fifteen combination patterns are possible.
- Long service life has been achieved through greatly reduced power requirements. No need to change battery for 48 hours when using combinations with combustible gases, or for 2,000 hours when using combinations without combustible gases.
OptionsPump Unit:- Used as a Extractive type when connected to "Mini" Multi-gas Detector XA-900 series (for one gas and two gases only).
Throw-in Set:- Can be used to detect gas in pits or manholes (for one gas and two gases only).
Specifications:
Gas Detected | Combustible gas (methane or isobutane) | Oxygen | Hydrogen sulfide | Carbon monoxide |
Detection Principle | Catalytic combustion | Galvanic cell | Electrochemical cell | Electrochemical cell |
Detection Range | 0-100% LEL (1% LEL resolution) | 0-25.0vol% (0.1vol% resolution) | 0.30.0ppm (0.5ppm resolution) | 0-300ppm (5ppm resolution) |
Indication Accuracy *1 | (? 10%) of full scale value | ? 0.5vol. | (?5%) of full scale value | (? 10%) of full scale value (1-150ppm) |
Alarm Set Value | 1st stage : 10% LEL 2nd stage : 25% LEL | Lower limit : 18.0vol% Upper limit : 25.0vol% | 1st stage : 10.0ppm 2nd stage : 20.0ppm | 1st stage : 50ppm 2nd stage : 150ppm |
Alarm Accuracy *1 | ?25% of Set Value | ?1.0vol% | ?30% of set value | ?30% of set value |
Response Time | 30s or less (90% response) | 20s or less (90% response) | 30s or less 90% response) | 30s or less (90% response) |
Concentration Indication | 3-digit LCD (when two gases are selected, the concentrations are displayed alternatively in every five seconds). |
Alarm Indication | 1st stage : Intermittent buzzer and LCD ''AL'' part flashing 2nd stage : Continuous buzzer and LCD ''AL'' part lighting |