Prism Gas Detection
Home  |  Profile  |  Products  |  Contact  |  Enquiry
Prism Gas Detection
Prism Gas Detection Prism Gas Detection
Prism Gas Detection Prism Gas Detection Prism Gas Detection
Prism Gas Detection Prism Gas Detection
Home »Occupational Safety Equipment
Prism Gas Detection

Prism Gas Detection
Prism Gas Detection Occupational Safety Equipment
We offer a comprehensive range of occupational safety equipment for protection from various contaminants at workplaces. Made of quality material, our safety equipment are based on latest technology and have been specially designed keeping the various requirements of our clients in mind. Our safety equipment is highly effective and reliable in reducing the employee exposure to hazards when engineering and administrative controls are not feasible.



 CO2 Monitor (Model : ZG106)

ZG 106 is a portable Taccurate handheld C02 Monitor
Which can be pulon desktop also tonieasire Ihe Co2 concentration and ambient temperature. ItusesNDIR technology to ifripro^e llie long term stability -Build-in several modes help you understand ambient air quality.




co2 monitor model zg106




Specifications
  • Method – NDIR
    Display – LCD
    Independent CO2 and Temperature readings.
    Calculates and Displays Ventilation Rates
    Sample Method – Diffusion or flow through (50-200 ml/min)

  • Performance – CO2 Channel
    Measurement Range : 0-3000 ppm display
    Display Resolution :
    • 1ppm at 0-1000 ppm
    • 5 ppm at 1000-2000 ppm
    • 10 ppm at 2000 – 3000 ppm
    Accuracy : ±50 ppm or ±5% of reading
    Repeatability : ±20 ppm
    Temperature Dependance : ±0.1% of resding per 0C or ±2 ppm per 0C whichever is greater refrenced to 2500
    Pressure Dependance : 0.13% of reading per mm Hg (Corrected via user input for attitude)
    Response Time : <4 min for 63% of step change
    Warm-Up Time : <50 seconds at 220C
    Calibration Interval : 12 months, offset adjustment using single gas at 0-1000 ppm CO. Full factory calibration available.

  • Performance – Temperature Channel
    Temperature Range : Display 32 to 122 0F (0 to 500C)
    Display Resolution : 0.1 0F (0.10C)
    Display Options : 0F 0C or Off. Set with Up, Down button
    Accuracy : ±2 0F (±10C)
    Response Time : 20-30 minutes
    Calibration interval : 12 months

  • Outputs
    OC : Normally Low, 100mA max. @24VAC, Adjustable set point, factory settings is 1000 ppm, hysteresis is 50 ppm
    One RJ-45 Connector digital output in RII protocol
    One Graphing Software ZyAura View (Under developing)

  • Power Supply Battery Type

    Two power supply types
    Battery type : Alkaline, AA* 4(80 hours)
    External : 6 VDC from external AC/DC adapter which is included in package (Use specified AC adaptor only)

    Power Requirement
    160 mA Peak, 15 mA average from 6V

  • General Operating Conditions

    Operating Temperatures :
    32-1220F (0-500C) 0-95% RH, non-condensing
    Storage Temperatures : -4 to 140 0F (-20 to 600C)

Power Button Enter Button Down Button
Up Button Model Button LCD Display
LED Light Function Label Gas Entry Hole
Power inlet Rj45 socket Housing Stand
Battery Cover AA Batteries *4





Our Products
Toxic Gas DetectorCombustable Gas DetectorFixed Gas Detector
Multi Gas DetectorOther Gas DetectorFlue Gas Analysers
Occupational Safety Equipment