Product Details:
Weight | 280 g |
Dimension | 66 x 11.8 x 50.8 mm |
Charging Time | 4 Hours with Rechargeable |
Relative Humidity | 5 to 95% Non-condensing |
Power Source | 2 "AA" batteries or rechargeable NiMh battery cartridge |
Product Details:
Power Source | 4 x AA (R6) manganese dry cells |
Dimension | W68xH155xD32 mm |
Minimum Detectable Leak rate | 2.1 x 10-6 Pa m/s 2.8g/year leak |
Minimum Detectable Concentration | 5 mm |
Operating Temperature | 0 to 400C |
Model | XP-704 | ||||
Detection Principle | Hot wire semiconductor | ||||
Gas Detected | R-22, R-123, R-23, R-32, R-134a, R-142b, R-404A, R-407A, R-407C, R-407E, R-410A, R-507A, R-290, R-600a, R-707 *Please specify gas to be detected | ||||
Minimum Detectable Concentration | 5ppm | ||||
Minimum Detectable Leak rate | 2.1 x 10-6 Pa m/s 2.8g/year leak | ||||
Response Time | 10s or less | ||||
Detection Indication | Intermittent buzzer and flashing lamp | ||||
Power source | 4 x AA (R6) dry cells | ||||
Battery life *1 | Approx. 3 continuous hours (by manganese dry cells) Approx. 9 continuous hours (by alkaline dry cells) |
||||
Low battery | BATT. Lamp goes off | ||||
Operating Temperature | 0 to 400C | ||||
Dimensions | W68 x H155 x D32mm | ||||
Weight | Approx. 400g | ||||
Standard Accessories | Probe with filter/moisture trap, check gas, filter element, Soft case, 4 x AA (R6) manganese dry cells, spare filters | ||||
Optional accessories | Battery charger (NiCd only), earphone |
Product Details:
Gas Type | Natural Gas |
Size | 200x120x80 mm |
Weight | 900 g |
Power Supply | 230 V AC |
Product Details:
Sound Level | 85 dB |
Range | Up to 1000 meter |
Capacity | 2 channel in 1 module |
Output | 4-20 mA |
Product Details:
Power Source | 4XAA alkaline dry cells or rechargeable NiCd battery pack |
Weight | 450 g |
Dimension | 82 x 162 x 36 mm |
Operation Temperature | 2 to 40 Deg C |
Product Details:
Weight | 3 Kg |
Dimension | W113xH234xD110 mm |
Operation Temperature | 0 to 40 Deg C |
Output | 4-20 mA |
Specifications:
|
Product Details:
Response Time | 5 Second |
Humidity | 0-95% RH |
Display | Analog scale, 45 mm, range switch |
Power Supply | 2.0 Ah/3.6 V |
Model | G-600 |
Gases | Combustible gases and vapors (examples: fuel vapors, natural gas, ethane, butane, methane, propane, hydrogen) |
Ranges | Micro (10 to 15% LEL) 0 to 100% LEL or 0 to % volume 0 to 100% volume |
Product Details:
Display Type | Digital |
Voltage | 100-260V AC |
Frequency | 50-60Hz |
Power | 10 W |
Product Details:
Battery Life | Up to 2000 hours |
Dimension | W56xH121xD32 mm |
Weight | 165 g |
Power Source | 3xAA (R6) alkeline dry cells |
Product Details:
Sound Level (dB) | 95 dB |
Power Supply | 2 batteries AA 1.5V |
Weight | 61-85 grams |
Dimension | W47xH88xD25 mm |
Product Details:
Detection Range | 0-100 vol% |
Operation Temperature | 0 to 40 Deg C |
Weight | 450 g |
Dimension | 82 x 162 x 36 mm |
Power Source | 4XAA alkaline dry cells or rechargeable NiCd battery pack |
Product Details:
Humidity | 95% RH (non-condensing) |
Weight | 65 g |
Dimension | W65xH50xD14 mm |
Power Source | 1 x AAA Alkaline dry cell |
Operation Temperature | 0 to 40 Deg C |
Product Details:
Display Type | Digital |
Response Time | 30 s max. (90% response) |
Operating Temperature | -20 to 50 Deg C |
Weight | 480 g |
Dimension | 79 x 161 x 43.5 mm |
Detection Range | 0 to 100% LEL |
Product Details:
Response Time | 10 sec. or less |
Operating Temperature | 0 Deg C to 40 Deg C |
Minimum Detectable Concentration | 2.1 x106 pa m3 /s, 2.8g/ year leak |
Detection Indication | Intermittent buzzer and flashing lamp |
Weight | Approx. 400 g |
Dimensions | 68 x 155 x 32 mm |
Gas Detected:
Standard Accessories:
Optional Accessories:
Product Details:
Size | 250 x 250 x 150 mm |
Warm Up Time | Less than 5 minutes |
Capacity | Up to 10 channels |
Power Supply | AC input 100-250 AC, 50-60 Hz |
Power Consumption | 1.5 W |
Product Details:
Humidity | 0-98% RH, Non-condensing |
Display | Graphic alpha-numeric display |
Power Source | Rechargeable NiMH battery pack |
Pressure Range | 800 to 1,300 mbar |
Weight | 750 g |
Product Details:
Size | 250 x 250 x 150 mm |
Warm Up Time | Less than 5 minutes |
Operating Temperature | -10 Deg C to 50 Deg C |
Power Consumption | 1.5 W |
Power Supply | 250 AC, 50-60 Hz |
Product Details:
Dimension | W47xH88xD25 mm |
Weight | 61-85 grams |
Acoustic | 95dB (30 cm) |
Temperature Range | -20 to 55 Deg C |
Pressure Range | 700 to 1,300hPa |
Product Details:
Battery Life | Typically 80 hrs. 4 x AA |
Measurement | Up to 10000 ppm |
Temperature Range | 0 to 50 Deg C |
Product Details:
Weight | 450 g |
Dimension | 82 x 162 x 36 mm |
Detection Range | 0-5,000 ppm or 0-10,000 ppm |
Product Details:
Weight | 759 g |
Dimension | W65xD22xH64 mm |
Battery Life | Up to 5000 hours (at 20*C without alarm) |
Operation Temperature | -10 Deg C to 50 Deg C |
Product Details:
Weight | 900 g |
Power Consumption | 5 W |
Dimension | W135xH247xD95 mm |
Sensor Material | Stainless Steel |
NH3 | Ammonia | 0 .. 200 0 .. 500 0 .. 1000 |
CL2 | Chlorine | 0 .. 50 0 .. 250 |
CLO2 | Chlorine dioxide | 0 .. 2 |
HCL | Hydrogen chloride | 0 .. 30 0 .. 200 |
HCN | Hydrogen | 0 .. 50 0 .. 250 |
C2H4O | Ethylene oxide | 0 .. 100 |
HF | Hydrogen fluoride | 0 .. 10 |
CO | Carbon monoxide | 0 .. 500 0 .. 2000 |
O3 | Ozone | 0 .. 1 0 .. 5 |
COCL2 | Phosgene | 0 .. 2 |
SO2 | Sulfur dioxide | 0 .. 50 0 .. 500 |
H2S | Hydrogen sulfide | 0 .. 200 0 .. 1000 |
SIH4 | Silane | 0 .. 50 |
NO2 | Nitrogen dioxide | .. 50 0 .. 200 |
NO | Nitrogen monoxide | 0 .. 300 0 .. 1500 |
H2 | Hydrogen | 0 .. 2000 0 .. 1 Vol, - % 0 .. 1 Vol, - % |
Product Details:
Weight | 759 g |
Battery Life | Up to 5000 hours (at 20*C without alarm) |
Power Source | 1 X AAA alkaline dry cell (LR 03) |
Response Time | 20s or less |
Specifications:
Model | XO-2100 |
Gas Detected | Oxygen |
Deletion Principle | Galvanic cell |
Sampling Method | Diffusion Type |
Detection Range (Service Range) | 0-25.0vol% (25.1-50.0vol%) |
Indication Accuracy (Under identical conditions) | ? 0.5vol% (As per JIS T8201) |
Alarm Set Value 1st stage 2nd stage | 19.5vol% 18.0vol% |
Response Time (90% response, at 20"..20C) | 20s or less |
Alarm indication | Intermittent buzzer, Red lamp flashing, LCD display, and vibrator |
Functions | Display of remaining battery level, peak hold, peak value memory function, self-diagnosis on activation, alarm functions (sensor faults, low battery, zero adjustment fault), display Selection function. |
Explosion-Proof Structure | Exib II BT3 |
Product Details:
Power Source | 4 x AA (R6) manganese dry cells |
Response Time | 10 S |
Weight | 400 g |
Operating Temperature | 0 to 40 Deg C |
Model | XP-703D | ||||
Detection Principle | Hot wire semiconductor | ||||
Gas Detected | Semiconductor manufacturering gases (arsine, phosphine, diborane, silane, etc.) | ||||
Minimum Detectable Leak rate Minimum Detectable Concentration | Arsine AsH3 1.0 x 10-7 0.2 | ||||
Response Time | 10s | ||||
Detection Indication | Intermittent buzzer and flashing lamp | ||||
Power source *1 | 4 x AA (R6) manganese dry cells | ||||
Battery life | Approx. 9 hours by alkaline dry cells (Approx. 3 hours by manganese dry cells) | ||||
Operating Temperature | 0 to 400C | ||||
Dimensions | W68 x H155 x D32mm | ||||
Weight | Approx. 400g | ||||
Standard Accessories | Soft case, Probe with filter/moisture trap, check gas, standard attachment, 4 x AA (R6) manganese dry cells, spare filters | ||||
Optional accessories | Battery charger (NiCd only), earphone |
Product Details:
Weight | 450 g |
Power Source | 4XAA alkaline dry cells or rechargeable NiCd battery pack |
Dimension | W82xH162xD36 mm |
Display | LCD |
Specifications:
Model | XP-3140 |
Gas Delected | Methane, Propane, Argon, Carbon dioxide, etc. (specify gas to be detected) |
Detection Principle | Thermal conductivity |
Sampling Method | Extractive |
Detection Range | 0-100vol% |
Indication Accuracy (under identical) | H range: 5% L range : 10% |
Alarm Set Value | 50vol% |
Display | LCD digital (with backlight) Digital display : 0-100% Digital bar display : Auto range changeover 0-10vol% or 0-30vol% (L range) 0-100vol% (H range) |
Alarm Indication | Gas Alarm : Intermittent buzer, Red lamp flashing Trouble alarm : Buzzer, Red lamp flashing, LCD Display |
Explosion-Proof Structure | Exibd II BT3 |
Operation Temperature | 0 to 400C |
Power Source | 4XAA alkaline dry cells or rechargeable NiCd battery pack |
Battery Life * 1 | Up to 30 hours (alkaline cells) Up to 7 hours (Special NiCd battery pack) |
Product Details:
Response Time | 30 s max |
Humidity | 95% RH (non-condensing) |
Weight | 480 g |
Dimension | W79xH161xD43.5 mm |
Specifications:
Model | XP-311 II |
Detectable gas | Combustible gas |
Detection principle | Catalytic combustion |
Gas sampling method | Automatic sampling by built-in pump |
Detection range | 0 to 100% LEL |
Indication accuracy *1 | ±5% LEL of full scale value |
Alarm set value | 20% LEL |
Alarm method | Buzzer sounds and red lamp flashes at gas alarm. |
Power supply *2 | Four AA alkaline batteries (LR6) or manganese batteries (R6PU or R6P) |
Continuous operating time *3 | AA alkaline batteries (LR6), 20°C, no alarm, backlight OFF: General: Approx. 10 hours Methane: Approx. 8 hrs. |
Response time *4 | 30 s max. (90% response) |
Operating temperature and humidity range | -20 to 50°C, 95% RH max. (with no condensation) |
Explosion-proof structure | Ex ibd II BT3 (intrinsically safe and flame-proof design) *5 |
Main functions | * Zero adjustment (Automatic zero adjustment for the sensor can be performed at startup and as required.) * Buzzer stop (The buzzer can be stopped using a switch when it sounds.) * Backlight (The backlight can be turned ON using a switch.) |
Product Details:
Weight | 450 g |
Power Source | 4 x AA alkaline dry cells or rechargeable NiCd battery pack |
Dimension | W82xH162xD36 mm |
Display | LCD |
Specifications:
Model | XP-3110 | ||||
Gas Detected | Combustible gases and vapors (specify gas to be detected) | ||||
Detection Principle | Catalytic combustion | ||||
Sampling Method | Extractive | ||||
Detection Range | 0-10% LEL and 0-100% LEL | ||||
Indication Accuracy (Under identical canditions) | 5% of full scale | ||||
Alarm Set Value | 20%LEL | ||||
Display | LCD digital (with backlight) Digital display: 0-100% Digital bar Display: Auto range changeover 0-10% LEL (L range) 0-100% LEL (H range) | ||||
Alarm Indication | Gas Alarm: Intermittent buzzer, Red lamp flashing Trouble alarm: Buzzer, Red lamp flashing, LCD display | ||||
Explosion-proof Structure | Exibd IIBT3 | ||||
Operation Temperature | 0 to 400C (-20 to 500C for Iso-butane specification) | ||||
Power Source | 4 x AA alkaline dry cells or rechargeable NiCd battery pack | ||||
Battery life *1 | Upto 20 hours (alkalin cells) Upto 5 hours (Special NiCd rechargeable battery pack) |
Product Details:
Display | 4 Digit LED |
Resolution | 0.1% |
Output | 4-20 mA |
Voltage | 12 to 24 V DC |
Product Details:
Measuring Range | 0-300 ppm |
Response Time | 30 sec |
Gas Detected | Carbon Monooxide |
Weight | 75 g |
Power Source | 1 X AAA alkaline dry cell |
Product Details:
Weight | 450 g |
Dimension | W82xH162xD36 mm |
Power Source | 4 x AA Alkaline dry cells |
Gas Detected | Oxygen |
Product Details:
Operating Temperature Range | -10 to 40 Deg C |
Dimension | W56xH121xD32 mm |
Weight | 165 g |
Product Details:
Measurement | Up to 3000 ppm |
Voltage | 0-10 V |
Display | LED Digital |
Product Details:
Weight | 165 g |
Dimension | W56xH121xD32 mm |
Operation Temperature | -10 Deg C to 40 Deg C |
Power Source | 3xAA (R6) alkaline dry cells |
Product Details:
Size | W250xH250xD150 mm |
Warm Up Time | Less than 5 minutes |
Power Consumption | 1.5 W |
Product Details:
Power Source | 1 X AAA alkaline dry cell (LR 03) |
Weight | 759 g |
Dimension | W65xD22xH64 mm |
Product Details:
Detection Range | 0-5,000 ppm or 0-10,000 ppm |
Power Source | 4xAAA alkaline dry cells |
Dimension | W82xH162xD36 mm |
Specifications:
Model | XP-3160 |
Gas Delected | Combustible gases and vapors (specify gas to be detected) |
Detection Principle | Catalytic cambustion |
Sampling Method | Extractive |
Detection Range | 0-5,000 ppm or 0-10,000 ppm |
Indication Accuracy (Under identical conditions) | H range : ?5% L range : ?10% |
Alarm Set Value | 250 or 500ppm |
Display | LCD digital (with backlight) Digital display : 0-5,000ppm or 0-1vol% Digital bar display: Auto range changeover 0-500ppm or 0-1,000ppm (L range) 0-5,000ppm or 0-10,000ppm (H range) |
Alarm Indication | Gas Alarm : Intermittent buzzer, Red lamp flashing Trouble alarm : Buzzer, Red lamp flashing, LCD display |
Explosion-Proof Structure | Exibd II BT3 |
Operation Temperature | 0 to 400C (-20 to 500C for Iso-butane specification) |
Power Source | 4xAA alkaline dry cells or rechargeable NiCd battery pack |
Ballery life *1 | Up to 20 hours (alkaline cells) Upto 5 hours (Special NiCd rechargeable battery pack) |
Dimensions | W82 x H162 x D36mm |
Weight | Approx. 450g (16oz.) (including battery) |
Standard Accessories | Soft case, 4xAAA alkaline dry cells, Gas sampling hose (1m), Probe with filter/moisture trap, spare filters |
Optional Accessories | 2-30m gas sampling hose, Gas dilution probe, Data download software (CD-ROM software and USB cable), Rechargeable NiCd battery pack with charger |
Product Details:
Power Source | 1 X AAA alkaline dry cell |
Weight | 75 g |
Operating Temperature | -10 to 40 Deg C |
Dimension | W65xD22xH64 mm |
Product Details:
Power Source | 3 x AA (R6) alkaline dry cells |
Dimension | W56xH121xD32 mm |
Weight | 165 g |
Gas Detected | Combustible gas (methane or isobutane) | Oxygen | Hydrogen sulfide | Carbon monoxide |
Detection Principle | Catalytic combustion | Galvanic cell | Electrochemical cell | Electrochemical cell |
Detection Range | 0-100% LEL (1% LEL resolution) | 0-25.0vol% (0.1vol% resolution) | 0.30.0ppm (0.5ppm resolution) | 0-300ppm (5ppm resolution) |
Indication Accuracy *1 | (? 10%) of full scale value | ? 0.5vol. | (?5%) of full scale value | (? 10%) of full scale value (1-150ppm) |
Alarm Set Value | 1st stage : 10% LEL 2nd stage : 25% LEL | Lower limit : 18.0vol% Upper limit : 25.0vol% | 1st stage : 10.0ppm 2nd stage : 20.0ppm | 1st stage : 50ppm 2nd stage : 150ppm |
Alarm Accuracy *1 | ?25% of Set Value | ?1.0vol% | ?30% of set value | ?30% of set value |
Response Time | 30s or less (90% response) | 20s or less (90% response) | 30s or less 90% response) | 30s or less (90% response) |
Concentration Indication | 3-digit LCD (when two gases are selected, the concentrations are displayed alternatively in every five seconds). | |||
Alarm Indication | 1st stage : Intermittent buzzer and LCD ''AL'' part flashing 2nd stage : Continuous buzzer and LCD ''AL'' part lighting |
Product Details:
Operating Temperature | 0 to 40 Deg C |
Weight | 400 g |
Dimension | W68xH155xD32 mm |
Power Source | 4 x AA (R6) manganese dry cells |
Product Details:
Display Type | Digital |
Power Source | 4XAA alkaline dry cells or rechargeable NiCd battery pack |
Weight | 400 g |
Operation Temperature | 0 to 40 Deg C |